Make decisions faster and treat patients sooner with TRUFORMA, the in-clinic biosensor testing platform.

truforma

Take control over the testing process from start to finish

Gold standard results available at the point of care

TRUFORMA assays adhere to the stringent testing standards found in reference lab settings levels, allowing you to diagnose challenging cases with confidence. Now, you can achieve reference lab performance levels – right in your clinic.

Groundbreaking technology

Bulk Acoustic Wave (BAW)

Put the same technology used in aerospace and telecommunications to work in your practice! Bulk Acoustic Wave (BAW) is an innovative, non-optical, fluorescence-free technology that delivers accurate, reliable results when assessing complex conditions.

1Signal in– An RF signal is delivered to the BAW sensor

2Frequency shift– The sensor resonance frequency changes as mass is added to the sensor surface

3Signal out– The modified RF signal is used to calculate a frequency shift due to mass binding

A confident diagnosis at your fingertips

myZomedica.com is your tool for expert advice! This companion application provides:
• Interactive charts and diagnostic tools
• Access to test results and reference ranges
• In-depth results interpretation and expert advice

Easy to use

Simple installation and a user-friendly interface gets tests running in no time.

Obtain a sample
Add sample to a cartridge
Insert a cartridge into TRUFORMA
Results in 20 minutes or less
Obtain a sample
Add sample to a cartridge
Insert a cartridge into TRUFORMA
Results in 20 minutes or less

Easy to use

Simple installation and a user-friendly interface gets tests running in no time.

Obtain a sample

Add sample to a cartridge

Insert a cartridge into TRUFORMA

Results in 20 minutes or less

1

2

3

4

Reference lab performance levels

TRUFORMA assays are evaluated and compared with those of the predicate industry gold standard, ensuring that they adhere to reference lab performance levels.

ASSAY CORRELATION (R) CV%
DYNAMIC RANGE

GOLD STANDARD

DYNAMIC RANGE
DOWNLOAD THE
WHITE PAPER
Total T4

Canine & Feline

0.93
<20%
0.45 - >30.0 μg/dL
0.5 - 15.0 μg/dL
TSH

Canine

0.99
<20%
0.05 - 10.0 ng/mL
0.03 - 12.0 ng/mL
TSH

Feline1

0.92
<20%
0.008 - 1.5 ng/mL
0.03 - 12.0 ng/mL
Free T4

Canine

0.93
<20%
4.0 - 77.2 pmol/L
3.9 - 77.2 pmol/L
Cortisol

Canine

0.97
<20%
0.349 - 24.0 μg/dL
1.0 - 50.0 μg/dL
eACTH

Canine

0.98
<20%
5 - 700 pg/mL
5 - 1250 pg/mL
eACTH

Equine

0.96
<20%
5 - 1250 pg/mL
5 - 1250 pg/mL
cPL

Canine

0.96
<20%
30 - 2000 µg/L
30 - 2000 µg/L
Cobalamin

Canine

0.92
<20%
150 - 1000 ng/L
150 - 1000 ng/L
Folate

Canine

0.94
<20%
2 - 50 µg/L
1 - 24 µg/L

1As compared to canine TSH assay. No predicate TSH assay has been optimized for felines.

Reference lab performance levels

TRUFORMA assays are evaluated and compared with those of the predicate industry gold standard, ensuring that they adhere to reference lab performance levels.

ASSAY
Total T4
Canine & Feline
TSH
Canine
TSH
Feline1
Free T4
Canine
Cortisol
Canine
eACTH
Canine
eACTH
Equine
cPL
Canine
Cobalamin
Canine
Folate
Canine
CORRELATION (R) CV%
DYNAMIC RANGE
GOLD STANDARD DYNAMIC RANGE DOWNLOAD THE WHITE PAPER
0.93 <20% 0.45 - >30.0 μg/dL 0.5 - 15.0 μg/dL
0.99 <20% 0.05 - 10.0 ng/mL 0.03 - 12.0 ng/mL
0.92 <20% 0.008 - 1.5 ng/mL 0.03 - 12.0 ng/mL
0.93 <20% 4.0 - 77.2 pmol/L 3.9 - 77.2 pmol/L
0.97 <20% 0.349 - 24.0 μg/dL 1.0 - 50.0 μg/dL
0.98 <20% 5 - 700 pg/mL 5 - 1250 pg/mL
0.96 <20% 5 - 1250 pg/mL 5 - 1250 pg/mL
0.96 <20% 30 - 2000 µg/L 30 - 2000 µg/L
0.92 <20% 150 - 1000 ng/L 150 - 1000 ng/L
0.94 <20% 2 - 50  µg/L 1 - 24  µg/L

1As compared to canine TSH assay. No predicate TSH assay has been optimized for felines.

Explore TRUFORMA Assays

The only feline-optimized TSH assay to help diagnose hyperthyroidism

The only assay on the market capable of detecting the low TSH concentrations that indicate feline hyperthyroidism, the TRUFORMA fTSH assay helps veterinarians separate euthyroid cats from hyperthyroid cats for a more accurate diagnosis.

The TRUFORMA fTSH assay helps veterinarians:

Screen

Create a thyroid profile to track trends and identify 1-to-3-year subclinical hyperthyroid phase

Diagnose

Identify 10-40% of early to mild hyperthyroid cats that have normal T4 levels

Monitor

Test for development of Iatrogenic Hypothyroidism (IH)

Screen

Create a thyroid profile to track trends and identify 1-to-3-year subclinical hyperthyroid phase

Diagnose

Identify 10-40% of early to mild hyperthyroid
cats that have normal T4 levels

Monitor

Test for development of
Iatrogenic Hypothyroidism (IH)

Reliable canine cortisol quantification

The TRUFORMA canine-optimized cortisol assay provides veterinarians with a rapid, reliable and accurate measurement of canine cortisol levels at the point of care.

Accurate cortisol measurements are key to diagnosing and monitoring adrenal dysfunction:

Cushing’s Disease

Low Dose Dexamethasone Suppression (LDDS) or ACTH Stimulation testing to diagnose hyperadrenocorticism

Addison’s Disease

ACTH Stimulation testing to diagnose hypoadrenocorticism

Monitoring

Monitoring for optimal medication dosing

Cushing’s Disease

Low Dose Dexamethasone Suppression (LDDS) or ACTH Stimulation testing to diagnose hyperadrenocorti

Addison’s Disease

ACTH Stimulation testing to diagnose hypoadrenocorticism

Monitoring

Monitoring for optimal medication dosing

The only in-clinic assay to help differentiate the cause of canine Cushing’s Disease

A reliable eACTH assay to help determine if your patient’s Cushing’s disease is caused by a pituitary tumor (PDH) or an adrenal tumor (ADH or FAT), TRUFORMA helps veterinarians set an optimal course of treatment before the client leaves the exam room. The eACTH assay may also be useful in differentiating the causes (primary vs. secondary) of Addison’s disease, as well as monitoring for optimal medication dosing.

A Complete Thyroid Diagnostic Panel

TRUFORMA’s innovative technology brings highly sensitive and specific Total T4(tT4), Free T4 (fT4), and TSH testing to point of care. TRUFORMA offers the ONLY in-clinic fT4 assay, allowing for confident diagnosis and treatment of complex thyroid conditions.

More products from ZOM•Dx

Zomedica’s growing portfolio of diagnostic products transform every step of the diagnostic process, from the collection to the analysis of diagnostic results.

The only fully automated digital microscope.

The only zero-touch vital signs remote monitor.

The only fully automated digital microscope.

The only zero-touch vital signs remote monitor.